Connect with us

Drilling News

FE BATTERY METALS DRILLS 1.17 PERCENT LITHIUM OXIDE OVER 2 METERS AT AUGUSTUS LITHIUM PROPERTY

FE BATTERY METALS DRILLS 1.17 PERCENT LITHIUM OXIDE OVER 2 METERS AT AUGUSTUS LITHIUM PROPERTY
Canada NewsWire
VANCOUVER, BC, March 8, 2023

VANCOUVER, BC, March 8, 2023 /CNW/ – FE Battery Metals Corp. (CSE: FE) (OTCQB: FEMFF) (WKN: A2JC89)  (“FE Ba…

Share this article:

Published

on

FE BATTERY METALS DRILLS 1.17 PERCENT LITHIUM OXIDE OVER 2 METERS AT AUGUSTUS LITHIUM PROPERTY

Canada NewsWire

VANCOUVER, BC, March 8, 2023 /CNW/ – FE Battery Metals Corp. (CSE: FE) (OTCQB: FEMFF) (WKN: A2JC89)  (“FE Battery Metals” or the “Company) is pleased to announce results of Drill Hole LC23-42 from 2023 exploratory drill program at its Augustus Lithium Property in Quebec, Canada. The drill hole LC23-42 intersected two pegmatites with widths of 16 metres (m) and 4 m, respectively, showing varying lithium grades from 164 to 250 meters drilled depth (see Table 1 for details).

Highlights
  • The upper pegmatite is 16m wide with average 0.41% Li2O or 1,911 parts per million (ppm) lithium (Li) at 164 m drilled depth, including a two-meter-wide zone grading 1.17% Li2O at 167 m depth.
  • The lower pegmatite is 4 m wide with average 0.13% Li2O or 588 parts per million (ppm) lithium (Li) at 235 m drilled depth.
  • There are anomalous values of other rare metals in these pegmatite zones as shown in the Table 1, of special interest is a 0.73m intersection at 165 m depth with 1,270 ppm cesium (Cs) and 3,450 ppm rubidium.  
  • The drill hole LC23-42 was drilled at location 5367949N, 287240E, UTM NAD 1983 Zone 18N, at azimuth 222.8 degrees and dip -47.4 with a drilled depth of 255 m. The drill hole was placed at the main Augustus zone.

To date, 50 drill holes with a cumulative core drilling of over 9,500 m have been completed at Augustus. The drill core is logged and sampled at the core shack using a rock saw. For quality control and quality assurance (QA/QC), field duplicates, standards and blanks are being inserted at industry standard intervals.

The samples were bagged and tagged using best practices and were delivered to Activation Laboratories (“ACTLABS”), Ancaster, Ontario for sample preparation and analyses using laboratories code Ultratrace 7 and sodium peroxide fusion (Na2O2) as summarized below. ACTLABS is an independent commercial, accredited ISO Certified Laboratory.

Code Ultratrace 7 – Peroxide Fusion – ICP and ICP/MS

Samples are fused with sodium peroxide in a Zirconium crucible. The fused sample is acidified with concentrated nitric and hydrochloric acids. The resulting solutions are diluted and then measured by ICP-OES and ICP-MS. All metals are solubilized.

ICP-MS
Fused samples are diluted and analyzed by Agilent 7900 ICP-MS. Calibration is performed using five synthetic calibration standards. A set of (10-20) fused certified reference material is run with every batch of samples for calibration and quality control. Fused duplicates are run every 10 samples.

ICP-OES
Samples are analyzed with a minimum of 10 certified reference materials for the required analytes, all prepared by sodium peroxide fusion. Every 10th sample is prepared and analyzed in duplicate; a blank is prepared every 30 samples and analyzed. Samples are analyzed using a Varian 735ES ICP and internal standards are used as part of the standard operating procedure. Source: https://actlabs.com/geochemistry/lithogeochemistry-and-whole-rock-analysis/peroxide-total-fusion/

Afzaal Pirzada, P.Geo., Geological Consultant of the Company, and a “Qualified Person” for the purposes of National Instrument 43-101 – Standards of Disclosure for Mineral Projects, has reviewed and approved the scientific and technical information contained in this news release.

About FE Battery Metals Corp

FE Battery Metals Corp is focused on identifying, exploring and advancing early-stage lithium pegmatite projects in Canada. The Company’s primary efforts have been on exploration projects located in Quebec, with its flagship property being the Augustus Lithium Property. Augustus is located in the immediate vicinity of Val d’Or Quebec where several historical prospects and a previously active lithium mine is located within a 10km radius from the property. North American Lithium mine (NAL) and the Authier Project are two notable projects in the area that highlight the potential of the Augustus Lithium Property.

ON BEHALF OF THE BOARD OF
FE BATTERY METALS CORP

“Gurminder Sangha”
Gurminder Sangha
President & Chief Executive Officer

Neither the Canadian Securities Exchange (CSE) nor its Regulation Services Provider accepts responsibility for the adequacy or accuracy of this news release and has neither approved nor disapproved the contents of this news release.

Forward-looking Information 

Except for the statements of historical fact, this news release contains “forward-looking information” within the meaning of the applicable Canadian securities legislation that is based on expectations, estimates and projections as at the date of this news release. “Forward-looking information” in this news release includes information about the Company’s information concerning the intentions, plans and future actions of the parties to the transactions described herein and the terms thereon.

The forward-looking information in this news release reflects the current expectations, assumptions and/or beliefs of the Company based on information currently available to the Company. In connection with the forward-looking information contained in this news release, the Company has made assumptions about the Company’s ability to obtain required approvals. The Company has also assumed that no significant events occur outside of the Company’s normal course of business. Although the Company believes that the assumptions inherent in the forward-looking information are reasonable, forward-looking information is not a guarantee of future performance and accordingly undue reliance should not be put on such information due to the inherent uncertainty therein.

Table 1: Drill Hole LC23-42 Sample assays highlights

Analyte Symbol

Depth

Depth

Total
Width

Li

Li2O

Be

Cs

Fe

Nb

Rb

Ta

Unit Symbol

From

To

ppm

%

ppm

ppm

%

ppm

ppm

ppm

Detection Limit

m

m

m

3

0.1

0.05

2.4

0.4

0.2

Analysis
Method

FUS-MS-Na2O2

1158001

164

165

1

1040

0.22

< 3

6.1

8.75

9.2

23.1

0.8

1158002

165

166.3

1.3

3390

0.73

40

1270

5.47

14.6

3450

9.7

1158003

166.3

167

0.7

2400

0.52

147

124

1.03

79.3

1210

40.6

1158004

167

168

1

5510

1.18

217

87

1.3

46.3

1450

31.4

1158005

168

169

1

5380

1.16

154

80.6

1.11

64

868

29.6

Including

167

169

2

5445

1.17

1158006

169

170

1

1790

0.38

96

95.5

1

50.6

900

41.7

1158007

170

171

1

76

0.02

141

17.3

0.97

61.5

162

44.9

1158008

171

172

1

338

0.07

202

47.8

0.94

66.5

602

48.8

1158009

172

173

1

740

0.16

128

33.6

0.4

97.5

977

66.6

1158011

173

174

1

2390

0.51

207

77.5

0.8

95.3

1980

128

1158012

174

175

1

22

0.00

9

5.7

0.21

98.6

50.7

112

1158013

175

175.6

0.6

99

0.02

26

17.6

0.7

47.2

245

45.6

1158014

175.6

176.4

0.8

3150

0.68

14

222

4.44

12.5

1650

2

1158015

176.4

177

0.6

4330

0.93

18

373

5.58

13.2

1480

4.8

1158016

177

178.2

1.2

238

0.05

49

46.5

1.42

80

791

25.5

1158017

178.2

179

0.8

890

0.19

15

354

6.68

7.4

933

1

1158018

179

180

1

704

0.15

< 3

29.9

8.15

3.7

134

0.3

Upper
Pegmatite

164

180

16

1911

0.41

169.9

2.879

49.85

994.5

37.25

1158019

235

236

1

408

0.09

4

36.7

3.54

6.9

363

0.9

1158021

236

237

1

175

0.04

28

33.6

1.01

96

250

53.8

1158022

237

238

1

1020

0.22

53

154

1.66

40.4

1280

34.7

1158023

238

238.5

0.5

430

0.09

28

54.2

1.4

24.5

594

35.8

1158024

238.5

239

0.5

911

0.20

13

128

2.98

8.6

696

2.4

Lower
Pegmatite

235

239

4

588.8

0.13

25.2

81.3

2.118

35.28

636.6

25.52

1158025

248

249

1

75

0.02

213

55.2

0.46

95.9

2710

54.6

1158026

249

250

1

55

0.01

228

52

0.84

77.1

2870

40.3

 

Note: A standard conversion factor of 2.15 was used to report Li to Li2O values
All intersections reported are based on drilled width and have not been converted to the true width.

SOURCE First Energy Metals Limited

drilling
drill program
intersection
drills
drill hole
cse-fe
first-energy-metals-limited
first energy metals limited
press-release

Share this article:

Base Metals

Valhalla Metals reports 21 metres of 6.84% CuEq at Sun Project, Alaska

Valhalla Metals Inc. [TSXV-VMXX; OTCQB-VMXXF] reported assay results from four diamond drill holes totaling 1,104…

Share this article:

Published

on

Continue Reading
Financing News

Capella Announces Definitive Agreement for the Sale of is Central Norway Copper-Cobalt Projects to NickelX and Financing Update

Capella Announces Definitive Agreement for the Sale of is Central Norway Copper-Cobalt Projects to NickelX and Financing Update
Canada NewsWire
VANCOUVER, BC, Oct. 17, 2023

VANCOUVER, BC, Oct. 17, 2023 /CNW/ – Capella Minerals Ltd (TSXV: CMIL) (OTC…

Share this article:

Published

on

By

Continue Reading
Drilling News

Canada Silver Cobalt Works Confirms Pegmatites up to 20 meters wide and 70 meters long at Sangster West

 

Pegmatite Confirmations and Advanced Geochemical Insights Propel Exploration Success

Coquitlam, BC – TheNewswire – October 17, 2023 – Canada Silver…

Share this article:

Published

on

By

Continue Reading

Trending